Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Braz. dent. sci ; 24(4, suppl 1): 1-13, 2021. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1349290

ABSTRACT

Objective: To compare the reproduction trueness and precision of dental casts made by the conventional, milling and 3D printing techniques. Material and Methods: From an upper right side half-arch reference model (RM), 72 models were obtained and divided into three groups: conventional (CM), milled (MM) and printed (PM). All models were scanned and converted into standard tessellation language (.STL) files. The files were superimposed using 3D analysis software, and statistical analysis was performed using the root mean square (RMS) values obtained. The Shapiro-Wilk test was used to assess normality, and the Kruskal-Wallis test was used to compare groups (ρ < ⍺; ⍺ = 0.05). The Mann-Whitney U test was used for multiple comparisons among groups (ρ < ਕ; ਕ = 0.017). Results: There were significant differences in trueness (ρ = 0.000; ρ <0.001) and precision (ρ = 0.000; ρ < 0.001) among the three dental cast groups. Regarding trueness, CM presented better results, followed by MM and PM. Regarding precision, MM showed better results, followed by PM and CM, which did not show significant differences. Conclusions: For dental cast reproduction the conventional technique has the best trueness and the milling technique has the best precision.(AU)


Objetivo: Comparar a fidelidade e precisão de reprodução de modelos de trabalho pelas técnicas convencional, de fresagem e de impressão 3D. Material e Métodos: A partir de um modelo de referência (MR) de uma hemi-arcada superior direita, foram obtidos 72 modelos divididos em três grupos: convencionais (MC), fresados (MF) e impressos (MI). Todos foram digitalizados e convertidos sob a forma de ficheiros .STL (standard tesselation language). Os ficheiros foram sobrepostos utilizando um software de análise 3D, e através dos valores RMS (raiz do valor quadrático médio) obtidos foi realizada a análise estatística. Para avaliação da normalidade foi utilizado o teste Shapiro Wilk e para a comparação entre grupos foi utilizado o teste Kruskal-Wallis (ρ < ⍺; ⍺ = 0.05). Para as comparações múltiplas entre grupos, foi utilizado o teste U de Mann-Whitney (ρ < ਕ; ਕ = 0.017). Resultados:Existem diferenças significativas de fidelidade (ρ = 0.000; ρ <0.001) e precisão (ρ = 0.000; ρ < 0.001) entre os três grupos. Em relação à fidelidade, MC apresentou melhores resultados, seguido por MF e MI. Em relação à precisão, MF apresentou melhores resultados, seguido por MI e MC, que não apresentaram diferenças significativas entre si. Conclusão: Para reprodução de modelos de trabalho, a técnica convencional é a que apresenta maior fidelidade e a técnica de fresagem a que apresenta maior precisão.(AU)


Subject(s)
Printing, Three-Dimensional
2.
Arq. bras. med. vet. zootec. (Online) ; 69(4)jul.-ago. 2017. ilus
Article in English | LILACS, VETINDEX | ID: biblio-876503

ABSTRACT

The aim of this study was to evaluate the use of polyamide 12 intramedullary rods in osteotomized humerus in cockerels (White Plymouth Rock) and analyze, by radiography and histopathology, bone consolidation and the formation of bone callus. Ten cockerels were subjected to transverse osteotomy of the right humeral diaphysis followed by the insertion of polyamide 12 locked rods, with two nails in each bone fragment. Radiographies obtained at the immediate pre and post-operative period, and every 7 days for 3 months revealed no perioperatory complications. Radiography revealed a radiopaque bone callus between the 4th and 5th week post-surgery. Histopathology detected an amphophylic material (polyamide 12 rod) in the intramedullary region and the proliferation of highly vascularized connective tissue between the rod and the cortical bone. This connective tissue was highly cellular with differentiation into osteoblasts. The collagen fibers varied from loose to dense and a differentiated bone matrix, containing osteocytes in gaps and the development of bone marrow, was also observed; indicating the formation of a bone callus without signs of implant rejection. The polyamide 12 intramedullary rod was effective in the stabilization of the fractures used in this experimental model, with no rejection reaction for at least 90 days.(AU)


O presente estudo teve como objetivo avaliar a implantação de hastes intramedulares de poliamida 12, em úmeros osteotomizados de galos (Plymouth Rock Branca), bem como avaliar a consolidação óssea, por meio da verificação da formação de calo ósseo, analisando exames radiográficos e histopatológicos. Os galos foram submetidos à osteotomia transversa da diáfise do úmero direito, sendo implantadas posteriormente as hastes de poliamida 12 bloqueada com dois parafusos em cada fragmento ósseo. Após o procedimento cirúrgico, foram realizadas radiografias nos momentos pré e pós-operatório imediato e, posteriormente, a cada sete dias, durante três meses, até a realização da eutanásia. Não houve complicações perioperatórias. Ao exame radiográfico, os animais apresentaram formação de calo ósseo radiopaco entre a quarta e quinta semanas de pós-operatório. Ao exame histopatológico, foi possível notar, em todos os animais, presença de material anfofílico (haste de poliamida 12) ocupando a região intramedular óssea, e entre a haste e as corticais ósseas, proliferação de tecido conjuntivo altamente vascularizado. Tal tecido apresentou-se altamente celular com diferenciação em osteoblastos. Notaram-se também fibras colágenas, variando de aspecto frouxo a denso, e observou-se formação de matriz óssea diferenciada com osteócitos em lacunas e formações de medula óssea, denotando formação de calo ósseo sem sinais de rejeição do implante. A haste intramedular de poliamida 12 foi eficaz para estabilização das fraturas utilizando-se esse modelo experimental, sem reação de rejeição pelo período de 90 dias.(AU)


Subject(s)
Animals , Chickens/surgery , Fracture Fixation, Intramedullary/veterinary , Fractures, Bone/surgery , Humerus/injuries , Nylons
3.
ImplantNewsPerio ; 2(3): 425-432, mai.-jun. 2017. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-847248

ABSTRACT

Objetivo: avaliar o torque de inserção de um novo desenho de implante. Material e métodos: pacientes foram recrutados para instalação de implantes, no período de março a dezembro de 2015. Dados como o diâmetro, o comprimento do implante, a sequência de fresagem, a área de instalação e o torque atingido foram considerados. A avaliação do torque foi realizada com um torquímetro cirúrgico. Resultados: foram avaliados 82 implantes, com diâmetros entre 3,5 mm e 5 mm, e comprimentos entre 7 mm e 16 mm, sendo instalados 46 implantes na mandíbula e 36 implantes na maxila. Os torques (média ± desvio-padrão) alcançados foram de 53 ± 9,9 Ncm para maxila e 57 ± 11,3 Ncm para mandíbula. Conclusão: o sistema de implantes Novo Colosso promoveu torque de inserção adequado, com boa estabilidade primária nos implantes.


Objective: to evaluate the insertion torque of a new implant design. Material and methods: patients were recruited for implant placement from March to December 2015. Data such as diameter, implant length, drilling sequence, installation area, and torque reached were considered. Torque evaluation was performed with a surgical torque wrench. Results: 82 implants were evaluated, with diameters between 3.5 mm and 5.0 mm, and lengths between 7 mm and 16 mm, with 46 implants in the mandible and 36 implants in the maxilla. The torques (mean ± standard deviation) reached 53 ± 9.9 Ncm for maxilla and 57 ± 11.3 Ncm for mandible. Conclusion: the Novo Colosso implant system promotes adequate insertion torque with good primary implant stability.


Subject(s)
Humans , Dental Implants/statistics & numerical data , Osseointegration , Osteotomy , Torque
SELECTION OF CITATIONS
SEARCH DETAIL